Cooling tower packing is one of the core components in the cooling tower, and its main function is to increase the contact area between water and air and improve the heat dissipation effect of water.

PVC Square Counter Flow Cooling Tower Packing Specification
There are different requirements for cooling tower packing, such as length and width, material or thickness, etc. Please tell us your detailed requirements so as to get the correct solution and provide a quotation. PT can cover all customer needs. Filler media can also be required in flame retardant or antibacterial performance.
W
| H | Gap | Angle |
600 | Any | 20 | 90° |
PVC Square Counter Flow Cooling Tower Packing Features
Vacuum molding with flame-retardant PVC material can improve the thermal performance of the filler by an average of 7.3% and prolong its service life.
Convenient inspection, no disassembly, and convenient cleaning.
Self-extinguishing PVC material is free from decay and biological erosion, and its applicable temperature is below 50℃.
Select products available with Mechanical Assembly technology.
Material:
PVC, PP, CPVC
Thickness:
0.32mm or customized (customized min order 3000 pieces)
PVC Square Counter Flow Cooling Tower Packing Customization options
Customized logo (Min. order: 3,000 pieces)
Customized packaging (Min. order: 3,000 pieces)
Graphic customization (Min. order: 3,000 pieces)
Signs That the PVC Square Counter Flow Cooling Tower Packing Needs Replacement
When it comes to maintaining the efficiency and performance of a cooling tower, recognizing the signs that indicate the need for fill replacement is crucial. Here are several key indicators that your cooling tower fill may need to be replaced:
-
Reduced Cooling Efficiency
If the cooling tower is not cooling the water as effectively as it used to, this could be a sign that the fill is clogged or damaged. This inefficiency can lead to higher operating costs and increased energy consumption.
-
Increased Energy Consumption
A cooling tower that is not functioning efficiently will require more energy to operate, which will be reflected in higher energy bills. If you notice an unexplained increase in your energy costs, it may be time to inspect and potentially replace the fill.
-
Visible Damage or Wear
Physical damage such as cracks, warping, or wear on the fill media is a clear indication that the fill is deteriorating and should be replaced. Additionally, if the support grid holding the fill is damaged, it can cause the fill to become misaligned or fall out of place.
-
Scaling and Fouling
Over time, minerals like calcium can accumulate on the fill media, creating scale deposits that reduce airflow and disrupt water distribution. This buildup can significantly impair the heat exchange process, decreasing the tower’s efficiency. If regular cleaning cannot remove the scale, replacement is necessary.
-
Uneven Water Distribution
If the fill media is clogged or damaged, water distribution becomes uneven. This can result in areas where water pools excessively, while other sections remain dry, reducing the overall effectiveness of the cooling process. Uneven water distribution can also lead to hot spots and reduced cooling capacity.
-
Increased Maintenance Frequency
If the cooling tower requires more frequent maintenance than usual, it may be a sign that the fill needs to be replaced. Frequent cleaning, repairs, or patching of the fill media can indicate that it is nearing the end of its service life.
-
Excessive Noise
Cooling towers typically generate some noise, but if you notice an increase in noise levels, especially during high load conditions, it could be due to worn-out fill media. This can be particularly noticeable if water is crashing against degraded fill sheets.
-
Water Buildup and Staining
When the fill media degrades, it can lead to water pooling and staining nearby systems. This is a sign that the fill is no longer effectively distributing water and needs to be replaced.
-
Foul Odors
Bacterial growth on the fill media can cause unpleasant odors. If you notice a strong, foul smell emanating from the cooling tower, it may be due to deteriorating fill media.
-
Corrosive Mineral Buildup
Minerals like rust and calcium carbonate can deposit on the fill media, attracting dirt and other pollutants. Over time, this can lead to corrosion and degradation of the fill media, necessitating replacement.
Characteristics of PVC Square Counter Flow Cooling Tower Packing
Counterflow cooling tower fill is one of the key components of a cooling tower, and its design and performance directly affect the efficiency and service life of the cooling tower. Here are the main characteristics of counterflow cooling tower fill:
1. PVC Square Counter Flow Cooling Tower Packing High Cooling Efficiency
The fill design in counterflow cooling towers allows hot water to be sprayed downward from the top of the tower, while air flows upward from the bottom, creating a counterflow contact between the two. This design significantly improves heat exchange efficiency. The fill increases the contact area and time between water and air, further optimizing the cooling effect.
2. Various PVC Square Counter Flow Cooling Tower Packing Types
There are several types of counterflow cooling tower fill, including S-wave fill, slanted cross fill, stepped trapezoidal wave fill, staggered sine wave fill, point wave fill, and hexagonal honeycomb fill. Each type of fill has its unique structural and performance characteristics, making them suitable for different cooling tower designs and operating conditions.
3. PVC Square Counter Flow Cooling Tower Packing Good Hydrophilicity and Film Formation
High-quality fill usually has good hydrophilicity, which allows water to form a uniform film on the surface of the fill, increasing the contact area between water and air, and thus improving cooling efficiency.
4. PVC Square Counter Flow Cooling Tower Packing Chemical Stability
The fill is typically made of materials such as polyvinyl chloride (PVC) or polypropylene (PP), which have good chemical stability and can withstand corrosion from acids, alkalis, and organic solvents.
5. PVC Square Counter Flow Cooling Tower Packing Flame Retardancy
Many types of fill have good flame retardancy, with an oxygen index usually above 30, making them safer to use.
6. PVC Square Counter Flow Cooling Tower Packing Low Airflow Resistance
The design of the fill usually takes into account airflow resistance to ensure that air can pass through the fill layer smoothly, thereby reducing the energy consumption of the fan.
7. PVC Square Counter Flow Cooling Tower Packing Ease of Maintenance and Replacement
The fill is often designed in a modular way, making it easy to disassemble, clean, and replace. This design not only facilitates daily maintenance but also extends the service life of the cooling tower.
8. PVC Square Counter Flow Cooling Tower Packing Adaptability to Various Operating Conditions
Counterflow cooling tower fill can adapt to a wide range of temperatures, from -35°C to 65°C, and maintain good performance even in high-temperature conditions.
9. PVC Square Counter Flow Cooling Tower Packing Reduced Drift Loss
The design of counterflow cooling towers minimizes the probability of water droplets being carried out by the airflow, thereby reducing water resource waste.
10. PVC Square Counter Flow Cooling Tower Packing Optimized Space Utilization
The fill in counterflow cooling towers usually adopts a film-type design, with a larger heat exchange area per unit volume, further optimizing space utilization.
PVC Square Counter Flow Cooling Tower Packing Selection, and Suggestions
Criteria for Selecting PVC Square Counter Flow Cooling Tower Packing Types
Selecting the appropriate fill type depends on the design of the cooling tower, its working conditions, and water distribution characteristics. Performance requirements, maintenance capabilities, and environmental factors also become significant factors.
PVC Square Counter Flow Cooling Tower Packing Performance Considerations for Different Applications
Film fills are commonly used in industrial applications that require a high level of cooling and controlled water quality. On the other hand, splash fills and water containing debris are appropriate where water quality may vary or where access for cleaning may be restricted because splash fill and water film fills are less liable to become fouled.
PVC Square Counter Flow Cooling Tower Packing Size Measurement
Please measure the following data for the quality and reliability requirements of your maintenance cooling tower or maintenance project to adapt to the design of cooling tower filling or components.

PVC Square Counter Flow Cooling Tower Packing Application
The application range of cooling tower PVC fills is: Industrial water cooling,Air compressor, Aluminum profile processing, Steam turbine, Power generation, Tannery, Electric furnace, Freezing Series, Air conditioning cooling system
PVC Square Counter Flow Cooling Tower Packing Shipment
Packing:
In bundle,wooden pallet or as your request.
Delivery time:
With in 10 days.

Our Services of PVC Square Counter Flow Cooling Tower Packing
-Pre-sale services
Based on the clients' requirements, we will offer product pictures, videos, quotation,information,
engineering drawings until you satisfied with it. Warmly welcome to visit our factory.
-Sale services
1 Providing production schedule photos to ensure you know every process.
2 Our experienced technician are available on the phone also internet, the clients can get instance
guidance by telephone,email, online service anytime, anywhere.
3 Also can arrange experienced technician to clients site for installation guidance, commissioning and training etc.
-After-sale services
Normally, the equipment warranty is 12 months since installation. We will keep in touch with our clients
to follow up the working condition of our machines, and offer support for maintenance.
Why choose us?
1. Highest quality
We are the manufacturer who adopts import raw materials. It is cheap price and guaranteed quality.
2. Most competitive price
We can adjustment the price according to your market demand’s changes,and also can launch a series of promotional activities in a bad economic environment.
3. Professional
We are specialized in producing and sells as development, methods and handling. We have 16 years experience.
4. Best service
Answering emails and solving questions timely. Delivery and update information on time.
Trust, good quality and service are the basic of long term business.