Product Description

The cooling tower filler is one of the core components in the cooling tower, and its main function is to increase the contact area between water and air and improve the heat dissipation effect of water. 


1180九宫格

Spindle Cooling Tower Filler Specification



There are different requirements for fillers, such as length and width, material or thickness, etc. Please tell us your detailed requirements so as to get the correct solution and provide a quotation. PT can cover all customer needs. Filler media can also be required in flame retardant or antibacterial performance.



W

H Gap Angle
850 1000 16 90°
1000 1000 16 90°


Spindle Cooling Tower Filler Material:

PVC, PP, CPVC

Spindle Cooling Tower Filler Thickness:

0.32 or customized (customized min order 3000 pieces)



Spindle Cooling Tower Filler Customization options


Customized logo (Min. order: 3,000 pieces)
Customized packaging (Min. order: 3,000 pieces)

Graphic customization (Min. order: 3,000 pieces)





Spindle Cooling Tower Filler Features



Features of Spindle Cooling Tower Filler

Spindle cooling tower filler is a high-performance filler widely used in industrial cooling systems. It is highly recognized in the market for its excellent heat transfer performance, low resistance design, corrosion resistance, and ease of cleaning and maintenance. Below are the detailed features of Spindle cooling tower filler:

I. Spindle Cooling Tower Filler Structural and Design Features

  1. Spindle Cooling Tower Filler Unique Corrugated Design

    Spindle cooling tower filler features a unique corrugated design that significantly increases the contact area between water and air, enhancing heat transfer efficiency. This design not only increases the specific surface area of the filler but also optimizes the water flow path, reducing water splashing and ensuring more water flows as a film, thereby improving heat exchange efficiency.

  2. Spindle Cooling Tower Filler Low Resistance Design

    The smooth surface of the filler allows gases and liquids to flow through easily without generating significant resistance. This low resistance design not only ensures the normal operation of the cooling tower system but also reduces energy consumption and improves energy efficiency.

  3. Spindle Cooling Tower Filler Modular Structure

    Spindle cooling tower filler is designed in a modular manner, facilitating installation and maintenance. This modular structure allows the filler to be flexibly combined according to the size and shape of the cooling tower, ensuring a perfect match between the filler and the cooling tower. This design also makes it convenient to quickly replace damaged parts, reducing maintenance time and cost.

  4. Spindle Cooling Tower Filler Positioning and Equal Spacing

    The filler adopts precise positioning and equal spacing, with a spacing of 15 millimeters. This design facilitates the formation of a large-area flowing water film perpendicular to the surface, promoting better contact with the airflow. The built-in vertical flow distributors ensure even distribution of air and water within the filler.

II. Spindle Cooling Tower Filler Material and Performance Features

  1. Spindle Cooling Tower Filler High-Quality Modified PVC Material

    Spindle cooling tower filler is typically made from modified PVC virgin sheets through vacuum forming. This material offers excellent corrosion resistance, aging resistance, and UV resistance, ensuring stable performance under various operating temperature conditions.

  2. Spindle Cooling Tower Filler Corrosion and High-Temperature Resistance

    The filler has good resistance to acids and alkalis, making it suitable for various harsh industrial environments. Its operating temperature range is from 65°C to -35°C, meeting the requirements for use under different climatic conditions.

  3. Spindle Cooling Tower Filler Flame Retardancy

    Spindle cooling tower filler has good flame retardancy, with an oxygen index exceeding 30, and some products even reaching above 40, ensuring safe usage.

  4. Spindle Cooling Tower Filler Strong Hydrophilic Performance

    The filler has strong hydrophilic properties and good film-forming characteristics, effectively reducing water drift loss and ensuring good cooling performance.

III. Spindle Cooling Tower Filler Cooling Effectiveness and Thermal Characteristics

  1. Spindle Cooling Tower Filler High-Efficiency Heat Exchange Performance

    Spindle cooling tower filler significantly enhances heat exchange efficiency by increasing the contact area between water and air. The optimized corrugated design and water flow path ensure more uniform water film distribution and extend the retention time of water in the filler, thereby improving cooling performance.

  2. Spindle Cooling Tower Filler Uniform Water Distribution

    The filler features a unique water distribution mechanism that ensures even distribution of cooling water. Uniform water distribution maximizes the performance of the filler, preventing localized overheating or insufficient cooling.

  3. Spindle Cooling Tower Filler Low Drift Rate

    Spindle cooling tower filler has an extremely low drift rate, below 0.001%, effectively reducing the waste of cooling water and lowering operating costs.

IV. Spindle Cooling Tower Filler Installation and Maintenance Features

  1. Spindle Cooling Tower Filler Convenient Installation Method

    The installation of Spindle cooling tower filler is very simple, typically using adhesive for assembly. The filler is relatively flat when manufactured, making it easy to transport and organize. During installation, simply trim the filler according to the size of the cooling tower and then glue it with special adhesive.

  2. Spindle Cooling Tower Filler Easy Maintenance and Cleaning

    The smooth surface of the filler makes it less likely to adhere to dirt, facilitating cleaning and maintenance. This design reduces the risk of blockage and scaling in the cooling tower, maintaining good working conditions. Meanwhile, the modular design makes it more convenient to replace the packing, reducing downtime.

  3. Spindle Cooling Tower Filler Long Service Life

    Spindle cooling tower filler has a long service life, typically lasting more than five years. Its aging and UV resistance ensure the stability of the filler during long-term use.

V. Spindle Cooling Tower Filler Application Scenarios

  1. Spindle Cooling Tower Filler Industrial Cooling

    Spindle cooling tower filler is widely used in industries such as chemical, power, and metallurgy, meeting the cooling requirements of various industrial environments. Its energy-efficient features make it an ideal choice for modern industrial cooling systems.

  2. Spindle Cooling Tower Filler Air Conditioning Systems

    In air conditioning systems, Spindle cooling tower filler effectively reduces the temperature of cooling water, improving the efficiency of air conditioning systems. Its low-noise and low-energy consumption features make it particularly suitable for use in residential areas and commercial buildings.

  3. Spindle Cooling Tower Filler Water Treatment Systems

    Spindle cooling tower filler can also be used in the water treatment process of cooling systems, serving to filter and purify water quality and prevent blockages and corrosion in cooling systems.

VI. Spindle Cooling Tower Filler Technical Parameters

  1. Spindle Cooling Tower Filler Dimensions

    The common dimensions of Spindle cooling tower filler are 950mm×950mm, with customizable lengths to meet user requirements.

  2. Spindle Cooling Tower Filler Sheet Spacing and Thickness

    The sheet spacing of the filler is typically 20mm, and the sheet thickness ranges from 0.30mm to 0.45mm. This design ensures the strength of the filler while reducing overall weight.

  3. Spindle Cooling Tower Filler Operating Temperature Range

    The operating temperature range of Spindle cooling tower filler is from 65°C to -35°C, ensuring stable performance under various climatic conditions.

  4. Spindle Cooling Tower Filler Corrosion Resistance

    The filler has strong corrosion resistance and can adapt to different industrial environments. Its surface is specially treated to effectively resist acid and alkali corrosion.



Spindle Cooling Tower Filler Size Measurement



Please measure the following data for the quality and reliability requirements of your maintenance cooling tower or maintenance project to adapt to the design of cooling tower filling or components.

宽度 1180





Application of Spindle Cooling Tower Filler



The application range of cooling tower PVC fills is: Industrial water cooling,Air compressor, Aluminum profile processing, Steam turbine, Power generation,  Tannery,  Electric furnace,  Freezing Series,  Air conditioning cooling system



Shippment of Spindle Cooling Tower Filler




Packing:

In bundle,wooden pallet or as your request.

Delivery time:

With in 10 days.

Selling units:

Single item.


Our Services Of Spindle Cooling Tower Filler


-Pre-sale services


Based on the clients' requirements, we will offer product pictures, videos, quotation,information,

engineering drawings until you satisfied with it. Warmly welcome to visit our factory.



-Sale services


1 Providing production schedule photos to ensure you know every process.

2 Our experienced technician are available on the phone also internet, the clients can get instance

guidance by telephone,email, online service anytime, anywhere.

3 Also can arrange experienced technician to clients site for installation guidance, commissioning and training etc.



-After-sale services


Normally, the equipment warranty is 12 months since installation. We will keep in touch with our clients

to follow up the working condition of our machines, and offer support for maintenance.

装车

Why choose us?


1. Highest quality


We are the manufacturer who adopts import raw materials. It is cheap price and guaranteed quality.

2. Most competitive price


We can adjustment the price according to your market demand’s changes,and also can launch a series of promotional activities in a bad economic environment.

3. Professional


We are specialized in producing and sells as development, methods and handling. We have 16 years experience.

4. Best service


Answering emails and solving questions timely. Delivery and update information on time.
Trust, good quality and service are the basic of long term business.


Previous: 
Next: 
Consult Your Cooling Tower Expert
Cooling Tower Parts
COOLING TOWER PARTS SUPPLIER
OEM Brands
Quick Links
COOLING TOWER PARTS SUPPLIER
Cooling Tower Parts
OEM Brands
Quick Links
COPYRIGHT © 2024 ZHEJIANG AOSHUAI REFRIGERATION CO., LTD. ALL RIGHTS RESERVED.