Hamon
Power Tower
10-15 days
| Availability: | |
|---|---|

The Hamon Cooling Tower Drift Eliminator is a critical component designed to minimize water drift and improve the operating efficiency of industrial cooling towers. By capturing water droplets carried by the exhaust airflow, drift eliminators significantly reduce water loss, chemical emissions, and environmental impact while ensuring compliance with industrial standards.
Our HAMON® compatible drift eliminators are engineered according to the original aerodynamic profile developed by France HAMON and are available in both flat-plate and half-wave sine-curve configurations. Manufactured using premium virgin PVC or polypropylene (PP) materials with UV-resistant and anti-aging additives, our products deliver excellent durability, low airflow resistance, and outstanding drift removal efficiency.
As a professional cooling tower parts manufacturer in China, we provide high-quality OEM replacement drift eliminators compatible with Hamon, BAC, EVAPCO, Marley, SPX, and many other leading cooling tower brands. Our products are widely exported to Europe, Southeast Asia, the Middle East, Russia, Kazakhstan, South America, and Africa.
A cooling tower drift eliminator is an airflow management component installed near the air outlet of a cooling tower. Its primary function is to capture fine water droplets entrained in the exhaust air and redirect them back into the cooling tower.
Without an efficient drift eliminator, circulating water containing treatment chemicals can escape into the atmosphere, causing:
Excessive water consumption
Chemical loss
Environmental pollution
Equipment corrosion
Increased operating costs
Modern industrial cooling towers rely on high-efficiency drift eliminators to keep drift loss below international environmental standards.
Manufactured according to the original HAMON fluid dynamic profile for maximum water droplet separation.
Half-wave type: ≤0.005%
Flat-plate type: ≤0.008%
This helps reduce water consumption while meeting stringent industrial environmental requirements.
Available materials include:
Virgin PVC
Virgin PP
HDPE (optional)
Benefits include:
UV resistance
Chemical resistance
Excellent toughness
Long service life
Anti-aging performance
The optimized blade profile minimizes pressure loss while maintaining excellent water separation efficiency, helping reduce fan energy consumption.
Suitable for cooling water treated with:
Chlorine
Bromine
Biocides
Scale inhibitors
Corrosion inhibitors
Designed for demanding industrial environments with excellent resistance to:
Low temperatures
High humidity
Continuous operation
Outdoor UV exposure
The modular snap-fit structure provides:
Quick installation
Easy maintenance
Reduced downtime
Simple replacement of damaged modules
| Item | Specification |
|---|---|
| Product Name | Hamon Cooling Tower Drift Eliminator |
| Material | Virgin PVC / PP / HDPE |
| Type | Flat Plate / Half-Wave |
| Color | Gray, Black, Customized |
| Width | Customized |
| Length | Customized |
| Thickness | Customized |
| Drift Loss | ≤0.005% (Half-Wave) |
| Drift Loss | ≤0.008% (Flat Plate) |
| UV Resistance | Excellent |
| Chemical Resistance | Excellent |
| Installation | Modular Snap-On |
| Service Life | 10–15 Years (Typical) |
| OEM Service | Available |
High-efficiency drift removal significantly decreases water loss, lowering make-up water requirements and reducing operating costs.
Since fewer water droplets escape, expensive water treatment chemicals remain inside the cooling system.
Our drift eliminators help industrial cooling towers comply with environmental regulations and reduce visible drift emissions.
Durable virgin materials resist:
Cracking
UV degradation
Chemical attack
Warping
This extends replacement intervals and lowers maintenance expenses.
The optimized airflow channel reduces pressure drop, helping cooling tower fans operate more efficiently and lowering energy consumption.
Compared with original HAMON spare parts, our compatible replacement products provide equivalent performance at significantly lower cost, making them an economical solution for cooling tower maintenance projects.
Our Hamon-compatible drift eliminators are widely used in:
Power plants
Petrochemical facilities
Steel mills
Cement plants
HVAC systems
Data centers
Pharmaceutical factories
Food processing plants
Mining operations
Paper mills
Industrial manufacturing facilities
Our products are suitable for replacing drift eliminators in many cooling tower brands, including:
Hamon
BAC (Baltimore Aircoil)
Marley (SPX)
EVAPCO
Liangchi
Kuken
Shinwa
VENTA-250
Other OEM cooling towers
Custom dimensions are available to match existing installations.
Over time, drift eliminators can become damaged or lose efficiency due to:
UV exposure
Continuous vibration
Chemical attack
Aging
Scaling
Physical damage
Deformation
Replacing worn drift eliminators can restore cooling tower performance, reduce water loss, and improve operating efficiency.
As a professional cooling tower parts manufacturer in China, we offer complete OEM and customized manufacturing services.
Our capabilities include:
Custom dimensions
Customized profiles
Mold development
Color customization
Private label production
Bulk export packaging
Technical support
Fast production
Every drift eliminator undergoes strict quality control throughout production.
The manufacturing process includes:
Virgin raw material inspection
PVC extrusion
Precision profile forming
Injection molding of PP brackets
Dimensional inspection
Assembly testing
Packaging inspection
Export packaging
Each batch is checked to ensure dimensional accuracy and reliable performance.
We are a professional supplier specializing in industrial cooling tower replacement parts.
Our advantages include:
Factory-direct pricing
OEM manufacturing experience
High-quality virgin raw materials
Strict quality inspection
Fast production
Global export experience
Custom manufacturing capability
Technical support before and after sales
Flexible order quantities
Reliable delivery schedules
Standard export packaging ensures products arrive safely.
Delivery options include:
FOB Ningbo
FOB Shanghai
CIF
CFR
EXW
Typical production lead time:
Samples: 5–7 days
Bulk orders: 15–25 days
We are both a manufacturer and an international trading company, providing factory-direct production with global export services.
We manufacture drift eliminators using virgin PVC, polypropylene (PP), and HDPE depending on project requirements.
Yes. We provide fully customized sizes, profiles, colors, and mounting configurations.
Our standard MOQ is 500 pieces. Smaller trial orders may also be discussed.
Our half-wave design achieves drift loss of ≤0.005%, while the flat-plate design achieves ≤0.008% under recommended operating conditions.
Our products are suitable for Hamon, BAC, Marley, EVAPCO, VENTA-250, and many other industrial cooling tower models.
We accept T/T, L/C, and Western Union. Other payment methods can be discussed for long-term partners.
We typically ship from Ningbo and Shanghai ports, but other Chinese ports can be arranged upon request.
If you are looking for a reliable Hamon Cooling Tower Drift Eliminator manufacturer, our factory offers high-quality OEM replacement solutions at competitive prices. Whether you require standard products or fully customized designs, our experienced engineering and production teams are ready to support your project.
Contact us today for product catalogs, technical drawings, free quotations, and worldwide shipping options.
![]() | ![]() |
1.Q: Are you Trading Company or Factory:
A:. We are Trading Company and also Factory
2.Q: What's your production ability for one month?
A:We can product Metric Tons per Month 200000 pcs .
3.Q: What's your MOQ?
A:500pcs
4.Q:What's your shipping port?
A:Ningbo ,shanghai or any port as your reqirement
5.Q: What's your Payment Terms?
A:L/C,T/T,Western Union
Try order is acceptable. Sample is available.
Welcome to inquire, we will feedback within 24 hours.
PRODUCT CATEGORY
Cooling Tower Fill | Cooling Tower Fan | Cooling Tower Speed Reduer | Cooling Tower Motor | Cooling Tower Drift Eliminator | Cooling Tower Fan Stacks | Cooling Tower Sprinkler Head | Cooling Tower Air Inlet Louver | Cooling Tower Basin | Cooling Tower Casing | Cooling Tower Nozzle | Cooling Tower Spray Pan | Cooling Tower Plastic Accessories
Marley/Spx | Liang Chi | Kingsun | EBABA/Shinwa | Spindle | Kuken | BAC | Brentwood | Evapco | Royden
HOME | PRODUCTS | OEM BRANDS | ABOUT US | BLOG | FAQ | CONTACT US
Cooling Tower Fill Cooling Tower Fan Cooling Tower Speed Reduer Cooling Tower Motor Cooling Tower Drift Eliminator Cooling Tower Fan Stacks Cooling Tower Sprinkler Head Cooling Tower Air Inlet Louver Cooling Tower Basin Cooling Tower Casing Cooling Tower Nozzle Cooling Tower Spray Pan Cooling Tower Plastic Accessories