The Liang Chi Drift Eliminators Cooling Tower is an important part of the cooling tower system, which is mainly used to collect and recover floating water generated in the cooling process to improve cooling efficiency and save water resources.
Liang Chi Drift Eliminators Cooling Tower Separator Specification
The water collector removes the small water droplets carried in the waste gas. If they are allowed to escape through the top of the tower together with the heated air, the harm and health problems will be minimized. The drift eliminator is designed to create a tortuous path for air flow. When the water drops pass through them, they are forced to change direction, hit the side wall of the drift eliminator, aggregate and discharge back to the wet section of the cooling tower.

H | L | Gap | Angle |
50 | Any | 20 | 90° |
Liang Chi Drift Eliminators Cooling Tower Separator Features
I. Liang Chi Drift Eliminators Cooling Tower Separator Introduction
Cooling towers play a vital role in industrial production, primarily functioning to reduce the temperature of circulating water through evaporative cooling. However, during operation, cooling towers tend to generate a significant amount of water droplet drift, which not only leads to water waste but also causes environmental pollution. Therefore, the drift eliminator, as one of the key components of a cooling tower, directly affects the operational efficiency and environmental performance of the cooling tower. Liangji drift eliminators, with their outstanding design and performance, have gained widespread recognition in the market. This article will provide a detailed introduction to the features of Liang Chi drift eliminators.
II. Liang Chi Drift Eliminators Cooling Tower Separator High-Efficiency Water Collection
A. Liang Chi Drift Eliminators Cooling Tower Separator Low Drift Loss
Liang Chi drift eliminators have extremely low drift loss rates. According to tests conducted by national authoritative testing departments, the drift loss rate, calculated based on the circulating water volume, can be as low as 0.001%, which is only one-tenth of the national standard's allowable value and reaches the advanced level of similar international products. For some models, such as the SC type, the drift loss rate can even be reduced to 0.0005%. This means that under the same circulating water volume, Liang Chidrift eliminators can effectively reduce water droplet drift loss and conserve a significant amount of water resources.
B. Liang Chi Drift Eliminators Cooling Tower Separator High Water Collection Efficiency
Liang Chi drift eliminators are designed to efficiently capture water droplets from the air. Their unique corrugated plate structure or honeycomb structure increases the contact area between the airflow and the drift eliminator, thereby enhancing the efficiency of water droplet capture. For example, Liang Chi's multi-dimensional zigzag structure drift eliminators further improve water collection performance by optimizing the airflow channels.
C. Liang Chi Drift Eliminators Cooling Tower Separator Strong Adaptability
Liang Chi drift eliminators are capable of adapting to different types of cooling towers and operating conditions. Whether it is a crossflow or counterflow cooling tower, Liang Chi drift eliminators can effectively reduce water droplet drift through their unique design. Moreover, they can accommodate various wind speeds and water flow conditions, ensuring high-efficiency water collection under different working scenarios.
III. Liang Chi Drift Eliminators Cooling Tower Separator Low Airflow Resistance Design
A. Liang Chi Drift Eliminators Cooling Tower Separator Optimized Airflow Channels
Liang Chi drift eliminators are designed to minimize airflow resistance. Their corrugated plate structure or honeycomb structure not only increases the contact area but also optimizes the airflow channels, allowing air to pass through the drift eliminator more smoothly. This low-resistance design helps reduce fan energy consumption, thereby lowering the operating costs of the cooling tower.
B. Liang Chi Drift Eliminators Cooling Tower Separator Significant Energy-Saving Effects
By reducing airflow resistance, Liang Chi drift eliminators can significantly decrease fan energy consumption. In practical applications, this low-resistance design not only improves the operational efficiency of the cooling tower but also reduces the running costs of the equipment. For example, compared with traditional drift eliminators, Liang Chi drift eliminators can reduce fan energy consumption by 10% to 20%.
C. Liang Chi Drift Eliminators Cooling Tower Separator Enhanced Cooling Efficiency
The low-resistance design of Liang Chi drift eliminators not only saves energy but also enhances the overall cooling efficiency of the cooling tower. Since air can pass through the drift eliminator more smoothly, the heat exchange performance of the cooling tower is improved, further optimizing the cooling effect.
IV. Liang Chi Drift Eliminators Cooling Tower Separator Durable Materials and Structure
A. Liang Chi Drift Eliminators Cooling Tower Separator High-Performance Materials
Liang Chi drift eliminators are typically manufactured from high-performance materials, such as PVC or fiberglass-reinforced plastic (FRP). These materials are known for their corrosion resistance, aging resistance, and high strength. For instance, PVC materials, when combined with carbon black, significantly enhance their UV resistance, effectively extending the service life of the drift eliminators.
B. Liang Chi Drift Eliminators Cooling Tower Separator Structural Design
The structural design of Liang Chi drift eliminators focuses on strength and stability. Their corrugated plate structure or honeycomb structure not only improves water collection efficiency but also ensures the stability of the drift eliminators during long-term operation. In addition, the assembly blocks of Liang Chi drift eliminators are designed with sufficient rigidity to withstand certain pressures, ensuring stable equipment operation.
C. Liang Chi Drift Eliminators Cooling Tower Separator Long Service Life
Liang Chi drift eliminators are designed for long service life, enabling them to operate stably in harsh industrial environments over extended periods. High-performance materials and optimized structural design ensure that the drift eliminators do not easily deform or get damaged during long-term use, further extending their service life.
V. Liang Chi Drift Eliminators Cooling Tower Separator Integrated Design
A. Liang Chi Drift Eliminators Cooling Tower Separator Integration
The drift eliminators of Liang Chi cooling towers are often designed as an integrated unit with the fill material and other components, reducing installation steps and maintenance workload. This design not only improves installation efficiency but also enhances the overall performance and reliability of the system.
B. Liang Chi Drift Eliminators Cooling Tower Separator Optimized Water and Air Distribution
The integrated design allows for closer coordination between the drift eliminator and the fill material, further optimizing the distribution of water and air. This optimized design not only improves cooling efficiency but also reduces the possibility of water droplet drift.
C. Liang Chi Drift Eliminators Cooling Tower Separator Ease of Maintenance
Another advantage of the integrated design is the ease of maintenance. Since the drift eliminator is integrated with the fill material and other components, maintenance tasks such as inspection and replacement can be carried out more conveniently, reducing maintenance time and costs.
VI. Liang Chi Drift Eliminators Cooling Tower Separator Environmental and Energy-Efficient
A. Liang Chi Drift Eliminators Cooling Tower Separator Water Conservation
The high-efficiency water collection performance of Liang Chi drift eliminators significantly reduces water droplet drift loss, conserving a substantial amount of water resources. In today's context of increasingly scarce water resources, this water-saving design holds significant environmental importance.
B. Liang Chi Drift Eliminators Cooling Tower Separator Energy Reduction
The low-resistance design of Liang Chi drift eliminators reduces fan energy consumption, lowering the operating costs of the cooling tower. This energy-saving design not only meets the modern industry's requirements for energy efficiency but also reduces the operational costs for businesses.
C. Liang Chi Drift Eliminators Cooling Tower Separator Reduced Environmental Pollution
By reducing water droplet drift, Liang Chi drift eliminators effectively minimize water mist pollution to the surrounding environment. This environmentally friendly design ensures that the operation of cooling towers has the least possible impact on the surrounding environment.
VII. Liang Chi Drift Eliminators Cooling Tower Separator Easy Maintenance and Cleaning
A. Liang Chi Drift Eliminators Cooling Tower Separator Suspended Installation
Liang Chi drift eliminators feature a suspended installation method, which eliminates the need for glue, making installation and cleaning more convenient. This design not only extends the service life of the drift eliminators but also reduces maintenance costs and downtime.
B. Liang Chi Drift Eliminators Cooling Tower Separator Easy Cleaning
The structural design of Liang Chi drift eliminators makes them easy to clean. Their corrugated plate structure or honeycomb structure allows water to pass through smoothly, reducing the accumulation of dirt. In addition, the suspended installation method makes the cleaning process more convenient.
C. Liang Chi Drift Eliminators Cooling Tower Separator Reduced Maintenance Costs
The durability and easy maintenance design of Liang Chi drift eliminators significantly reduce maintenance costs. High-performance materials and optimized structural design ensure that the drift eliminators do not easily get damaged during long-term use, reducing the frequency of replacements. Meanwhile, the suspended installation method makes maintenance tasks more efficient, further reducing maintenance costs.
VIII. Liang Chi Drift Eliminators Cooling Tower Separator Low-Noise Operation
A. Liang Chi Drift Eliminators Cooling Tower Separator Optimized Airflow Channels
Liang Chi cooling towers are designed to operate with low noise levels, and the drift eliminator, as an important component of the cooling tower, also plays a role in this aspect. By optimizing the airflow channels and reducing water droplet collisions, the drift eliminator can effectively lower noise levels.
B. Liang Chi Drift Eliminators Cooling Tower Separator Improved Environmental Quality
Low-noise operation not only improves the environmental quality around the cooling tower but also meets the modern industry's demand for low-noise equipment. In urban environments, low-noise operation is particularly important as it reduces interference to surrounding residents and businesses.
C. Liang Chi Drift Eliminators Cooling Tower Separator Compliance with Environmental Requirements
Low-noise operation complies with modern environmental requirements, reducing the impact of noise pollution on the environment. The low-noise design of Liang Chi cooling towers ensures that they meet environmental standards in various industrial scenarios.
IX. Liang Chi Drift Eliminators Cooling Tower Separator Adaptability to Various Cooling Tower Types
A. Liang Chi Drift Eliminators Cooling Tower Separator Wide Applicability
Liang Chi drift eliminators are designed to be highly adaptable, capable of meeting the needs of different types of cooling towers. Whether it is a crossflow or counterflow cooling tower, Liangji drift eliminators can effectively capture water droplets through their unique discharge angles and structural designs.
B. Liang Chi Drift Eliminators Cooling Tower Separator Customized Solutions
Liang Chi also offers customized solutions, designing and manufacturing drift eliminators based on specific customer requirements and cooling tower operating conditions. This customized service ensures that the drift eliminators maintain high-performance efficiency under various complex working conditions.
C. Liang Chi Drift Eliminators Cooling Tower Separator Optimized Installation Solutions
The installation solutions for Liang Chi drift eliminators are optimized to accommodate different cooling tower structures and installation environments. Whether it is a new cooling tower or a retrofit project, Liang Chi drift eliminators can provide efficient installation solutions.
X. Liang Chi Drift Eliminators Cooling Tower Separator Compliance with International Standards
A. Liang Chi Drift Eliminators Cooling Tower Separator Authoritative Certification
The design and manufacturing of Liang Chi cooling towers and their drift eliminators comply with international standards, such as CTI certification. This means that Liang Chi's products have undergone rigorous testing and verification in terms of performance, quality, and safety, meeting the needs of different regions around the world.
B. Liang Chi Drift Eliminators Cooling Tower Separator High-Quality Standards
The production process of Liang Chi drift eliminators strictly follows high-quality standards, ensuring that each unit meets the design requirements. From material selection to manufacturing processes and final product testing, Liang Chi employs a stringent quality control system.
C. Liang Chi Drift Eliminators Cooling Tower Separator International Recognition
With its outstanding performance and high-quality standards, Liang Chi cooling tower drift eliminators have gained widespread recognition in the international market. Their
Liang Chi Drift Eliminators Cooling Tower Separator Structural Installation Drawing
The structural position of the water drift eliminator is shown in the following figure.
Please tell us the model or size of the cooling tower, and we will estimate the number of sheets needed to replace the cooling tower.

Liang Chi Drift Eliminators Cooling Tower Separator Application
The application range of cooling tower PVC fills is: Industrial water cooling,Air compressor, Aluminum profile processing, Steam turbine, Power generation, Tannery, Electric furnace, Freezing Series, Air conditioning cooling system
Liang Chi Drift Eliminators Cooling Tower Separator Shippment
Packing:
Wooden pallet.
Delivery time:
Within 10 days.

Our Services Liang Chi Drift Eliminators Cooling Tower Separator
-Pre-sale services
Based on the clients' requirements, we will offer product pictures, videos, quotation,information,
engineering drawings until you satisfied with it. Warmly welcome to visit our factory.
-Sale services
1 Providing production schedule photos to ensure you know every process.
2 Our experienced technician are available on the phone also internet, the clients can get instance
guidance by telephone,email, online service anytime, anywhere.
3 Also can arrange experienced technician to clients site for installation guidance, commissioning and training etc.
-After-sale services
Normally, the equipment warranty is 12 months since installation. We will keep in touch with our clients
to follow up the working condition of our machines, and offer support for maintenance.
Why choose us?
1. Highest quality
We are the manufacturer who adopts import raw materials. It is cheap price and guaranteed quality.
2. Most competitive price
We can adjustment the price according to your market demand’s changes,and also can launch a series of promotional activities in a bad economic environment.
3. Professional
We are specialized in producing and sells as development, methods and handling. We have 16 years experience.
4. Best service
Answering emails and solving questions timely. Delivery and update information on time.
Trust, good quality and service are the basic of long term business.