Views: 0 Author: Site Editor Publish Time: 2025-12-11 Origin: Site
In evaporative cooling equipment, Evapco cooling towers are widely used in various industries worldwide for their high efficiency, reliability, and durability. However, with long-term operation, the cooling tower fill inside the cooling tower will gradually age, become clogged or damaged, leading to a decrease in heat dissipation efficiency, an increase in energy consumption, and even affecting the stable operation of the equipment. Therefore, regular cooling tower fill replacement is an important step in maintaining the optimal performance of Evapco cooling tower.
![]() | ![]() |
The cooling tower fill function is one of the most critical performance cores inside the cooling tower, and its functions include:
The filler forms a thin film or droplets of water through a special geometric structure, thereby improving the efficiency of evaporative cooling.
Allow the water flow to fall evenly, avoid short flows or hollow areas, and ensure that the entire tower achieves maximum heat exchange efficiency.
Improve the heat transfer efficiency between air and water per unit volume.
Efficient fill structure reduces the load on fans and pumps, saving operating costs.
Evapco cooling towers have strict requirements for fill structure and material, so maintaining their good condition is crucial.
Reduces heat transfer efficiency by 20-40%
Increased energy consumption
Deformation or embrittlement of packing material
Accelerated corrosion and aging
1.Cooling effect decreases (water outlet temperature increases)
2.The energy consumption of fans and motors has significantly increased
3.The pressure of the water pump increases
4.Equipment noise increases
5.Potential increased risk of Legionella bacteria
The common materials for Evapco fillers are PVC or PP, and their service life is usually:
5-8 years (moderate temperature, good water quality)
8-12 years (high temperature, industrial environment)
If the on-site water quality is poor and the maintenance frequency is low, the lifespan may be shortened to 3-5 years.
When carrying out cooling tower fill replacement, professional construction steps should be followed:
1)Power outage
2)Drainage
3)Ensure construction space
1)Be careful to remove damaged and aged fillers
2)Avoid damaging the tower foundation support
1)Remove silt and scale
2)Internal disinfection to reduce bacteria and algae
3)Check the sprinkler system and float
1)Cut and match size according to Evapco model
2)Install correctly according to the direction of airflow
3)Ensure that the packing is stacked tightly without gaps
1)Start the system and check the water distribution
2)Monitor the water temperature and airflow situation
3)Record the performance parameters after replacement
Cooling Tower Fill | Cooling Tower Fan | Cooling Tower Speed Reduer | Cooling Tower Motor | Cooling Tower Drift Eliminator | Cooling Tower Fan Stacks | Cooling Tower Sprinkler Head | Cooling Tower Air Inlet Louver | Cooling Tower Basin | Cooling Tower Casing | Cooling Tower Nozzle | Cooling Tower Spray Pan | Cooling Tower Plastic Accessories
Marley/Spx | Liang Chi | Kingsun | EBABA/Shinwa | Spindle | Kuken | BAC | Brentwood | Evapco | Royden
HOME | PRODUCTS | OEM BRANDS | ABOUT US | BLOG | FAQ | CONTACT US
Cooling Tower Fill Cooling Tower Fan Cooling Tower Speed Reduer Cooling Tower Motor Cooling Tower Drift Eliminator Cooling Tower Fan Stacks Cooling Tower Sprinkler Head Cooling Tower Air Inlet Louver Cooling Tower Basin Cooling Tower Casing Cooling Tower Nozzle Cooling Tower Spray Pan Cooling Tower Plastic Accessories