You are here: Home » Cooling Tower Part » Cooling Tower Nozzle » Cooling Nozzle for Sewage Cooling Tower

loading

Cooling Nozzle for Sewage Cooling Tower

The nozzle is made of ABS plastic by one-time injection molding, which has high strength and long service life.
  • APZ13

  • PT

  • 10 days

Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Product Description

The Cooling Nozzle for Sewage Cooling Tower is made of ABS plastic by one-time injection molding, which has high strength and long service life. The Cooling Nozzle for Sewage Cooling Tower distributes water evenly, and the working water pressure is low (the working pressure at the nozzle outlet is only 0.6H20), and the pressure adaptation range is wide, so it is not easy to block. Because it has a specially designed locking and anti-loosening device, it can be firmly connected with the water distribution pipe without falling off, which can ensure the long-term safe operation of the water distribution system. Under normal conditions, the service life of the head is 20 years.


Cooling Nozzle For Sewage Cooling Tower Specification



Material ABS
Color White

  

When Cooling Nozzle for Sewage Cooling Tower Need To Be Replaced:


Cooling Nozzle for Sewage Cooling Tower Clogging

  • Cause: Over long-term operation, impurities, scale, and microorganisms in the water can adhere to the inside of the Cooling Nozzle for Sewage Cooling Tower or the spray holes, leading to clogging.

  • Symptoms: Insufficient spray water volume and uneven distribution, resulting in reduced cooling efficiency.

  • Solution: If the nozzles are severely clogged and cannot be cleaned and unblocked, they need to be replaced.

Cooling Nozzle for Sewage Cooling Tower Wear or Damage

  • Cause: The Cooling Nozzle for Sewage Cooling Tower may wear out or get damaged due to long-term exposure to water flow impact and corrosion.

  • Symptoms: The spray shape and water flow of the nozzles change, failing to meet the designed water distribution requirements.

  • Solution: Regularly inspect the condition of the nozzles. If they are severely worn or damaged, they should be replaced promptly.

Cooling Nozzle for Sewage Cooling Tower Aging

  • Cause: The durability of Cooling Nozzle for Sewage Cooling Tower materials is limited. When exposed to high temperatures and high humidity for a long time, the nozzles will gradually age.

  • Symptoms: The performance of the nozzles declines, such as reduced water flow and altered spray angles.

  • Solution: Even if the nozzles do not show obvious damage, they should be replaced regularly based on their service life and actual operating conditions.

Cooling Nozzle for Sewage Cooling Tower Uneven Water Distribution

  • Cause: Nozzle blockage, damage, aging, and deformation of the water distribution pipes can all lead to uneven water distribution.

  • Symptoms: The heat exchange effect of the cooling tower packing layer deteriorates. Some parts of the packing do not have enough water coverage, resulting in dry spots.

  • Solution: Inspect the condition of the nozzles, clean or replace the clogged or damaged ones, and check whether the water distribution pipes are tilted or deformed. If necessary, repair or replace them.

Cooling Nozzle for Sewage Cooling Tower Reduced Cooling Efficiency

  • Cause: Problems with the nozzles lead to poor water flow, distribution, and spray effect of the spray water, affecting the heat exchange efficiency of the cooling tower.

  • Symptoms: The temperature of the cooled water does not meet the design requirements, and the system operating efficiency decreases.

  • Solution: Inspect the nozzles for blockages, wear, or aging. If problems are found, replace the nozzles promptly.

Cooling Nozzle for Sewage Cooling Tower Material Not Suitable for Water Quality

  • Cause: If the water quality of the cooling tower is poor and contains a large amount of corrosive substances, and the nozzle material is not corrosion-resistant, the nozzles will be corroded and damaged.

  • Symptoms: Cracks, holes, or deformation appear in the nozzles.

  • Solution: Replace the nozzles with materials that have better corrosion resistance, such as stainless steel or engineering plastics.

Cooling Nozzle For Sewage Cooling Tower Features




Cooling Nozzle for Sewage Cooling Tower are key components in the wastewater treatment process, used for spraying, mixing, and stirring operations. They have the following characteristics:

1. Cooling Nozzle for Sewage Cooling Tower High Corrosion Resistance

Cooling Nozzle for Sewage Cooling Tower often need to operate in harsh chemical environments and are typically made of corrosion-resistant materials, such as stainless steel (grades 304, 316), polypropylene (PP), and polyvinylidene fluoride (PVDF). These materials can withstand acids, alkalis, and corrosive substances in wastewater, extending the service life of the nozzles.

2. Cooling Nozzle for Sewage Cooling Tower Anti-Clogging Design

Cooling Nozzle for Sewage Cooling Tower are usually designed with large passages to reduce the likelihood of clogging. For example, spiral nozzles have a spiral groove structure and large orifice design to minimize clogging. Additionally, some nozzles are equipped with filters or self-cleaning functions.

3. Cooling Nozzle for Sewage Cooling Tower Uniform Spray Distribution

Cooling Nozzle for Sewage Cooling Tower can produce uniform spray patterns, ensuring thorough mixing of wastewater with treatment chemicals. For instance, flat spray nozzles can generate wide-angle sprays with large coverage areas and evenly distributed droplets. Spiral nozzles increase the contact area between liquid and gas through their spiral spray pattern.

4. Cooling Nozzle for Sewage Cooling Tower Multiple Spray Patterns Available

Cooling Nozzle for Sewage Cooling Tower come in various spray patterns, including flat fan, solid cone, and hollow cone. Different spray patterns are suitable for different wastewater treatment processes. For example:
  • Flat fan nozzles are used for surface cleaning and large-area spraying.
  • Spiral nozzles are suitable for exhaust gas scrubbing and wastewater mixing.
  • Solid cone nozzles are used in applications requiring uniform coverage.

5. Cooling Nozzle for Sewage Cooling Tower Easy Installation and Maintenance

Cooling Nozzle for Sewage Cooling Tower are designed for easy installation and replacement. For example, some nozzles feature quick-disconnect designs for rapid replacement or cleaning. Additionally, the materials and structural design of the nozzles enable them to operate stably over the long term in harsh environments.

6. Cooling Nozzle for Sewage Cooling Tower Efficient Mixing and Stirring

Certain Cooling Nozzle for Sewage Cooling Tower achieve efficient mixing and stirring through intermittent spraying of compressed air or liquid. For example, nozzles used for wastewater mixing and stirring can generate large bubbles in a short time, preventing sludge settling and ensuring uniform distribution of suspended solids.

7. Cooling Nozzle for Sewage Cooling Tower Energy and Water Conservation

Cooling Nozzle for Sewage Cooling Tower optimize spray performance, reducing the use of water and chemicals, which aligns with energy-saving and environmental protection goals. For example, flat fan nozzles can produce high-impact sprays at high pressure while conserving water.
These characteristics enable wastewater nozzles to meet the requirements of corrosion resistance, anti-clogging, and uniform spray distribution in the wastewater treatment process, making them indispensable components in wastewater treatment systems.


Cooling Nozzle For Sewage Cooling Tower Application



Cooling Nozzle for Sewage Cooling Tower Practical Application Suggestions

  • Cooling Nozzle for Sewage Cooling Tower Optimize Design:

    Choose the appropriate nozzle type and arrangement based on the specific conditions of the cooling tower to achieve the best cooling effect and economic benefits.
  • Cooling Nozzle for Sewage Cooling Tower Regular Maintenance:

    Regularly check the wear and blockage of the nozzles, and replace damaged nozzles in time to ensure the normal operation of the cooling tower.
  • Cooling Nozzle for Sewage Cooling Tower Adapt to Operating Conditions:

    In the winter with low load or low circulation water volume, the uniformity of water distribution can be guaranteed by adjusting the number of running water pumps or using bypass pipes.


By choosing and arranging the nozzles reasonably, the sewage cooling tower can achieve efficient cooling effects while reducing energy consumption and maintenance costs.


ABS Cooling Tower Water Nozzle Shippment




Cooling Nozzle for Sewage Cooling Tower Packing:

Wooden,cartons,custom package.


Cooling Nozzle for Sewage Cooling Tower Delivery time:

With in 10 days.


未标题-1

Our Services Of Cooling Nozzle For Sewage Cooling Tower


-Pre-sale services


Based on the clients' requirements, we will offer product pictures, videos, quotation,information,

engineering drawings until you satisfied with it. Warmly welcome to visit our factory.



-Sale services


1 Providing production schedule photos to ensure you know every process.

2 Our experienced technician are available on the phone also internet, the clients can get instance

guidance by telephone,email, online service anytime, anywhere.

3 Also can arrange experienced technician to clients site for installation guidance, commissioning and training etc.


-After-sale services


Normally, the equipment warranty is 12 months since installation. We will keep in touch with our clients

to follow up the working condition of our machines, and offer support for maintenance.


Why choose us?


1. Highest quality of Cooling Nozzle for Sewage Cooling Tower


We are the manufacturer who adopts import raw materials. It is cheap price and guaranteed quality.

2. Most competitive price of Cooling Nozzle for Sewage Cooling Tower


We can adjustment the price according to your market demand’s changes,and also can launch a series of promotional activities in a bad economic environment.

3. Professional of Cooling Nozzle for Sewage Cooling Tower


We are specialized in producing and sells as development, methods and handling. We have 16 years experience.

4. Best service of Cooling Nozzle for Sewage Cooling Tower


Answering emails and solving questions timely. Delivery and update information on time.
Trust, good quality and service are the basic of long term business.



Previous: 
Next: 
Consult Your Cooling Tower Expert
Cooling Tower Parts
COOLING TOWER PARTS SUPPLIER
OEM Brands
Quick Links
COOLING TOWER PARTS SUPPLIER
Cooling Tower Parts
OEM Brands
Quick Links
COPYRIGHT © 2024 ZHEJIANG AOSHUAI REFRIGERATION CO., LTD. ALL RIGHTS RESERVED.