Compression molding process, is the current advanced manufacturing processof FRP fan stacks, it uses impregnated film material as raw material, the product pressedby hydraulic press for power, first of all, a certain amount of molding material placedin the metal mold, and then in 150-170'c temperature and 1500-4000 tons of pressuremolding, the product size is accurate, the surface is smooth, and the product size isaccurate. lt can be formed once, the production efficiency is high, and the productquality is stable, suitable for mass production of various FRP products.
Water Cooling Tower Molded Fan Stacks Specification

No. | Model | H1 mm | H2 mm | Φ mm | Φ1 mm | Φ2 mm | Φ3 mm | PCS of fan stack | Screws type | Screws qty |
1 | ABF-80D | 3800 | 1650 | 8070 | 9480 | 9660 | 8420 | 40 | M12*40 | 1240Set |
2
| ABF-85D | 3800 | 1650 | 8610 | 10020 | 10200 | 8950 | 44 | M12*40 | 1364Set |
3 | ABF-92D | 3800 | 1650 | 9220 | 10630 | 10810 | 9570 | 48 | M12*40 | 1488Set |
4 | ABF-98D
| 3800 | 1650 | 9820 | 11230 | 11410 | 10170 | 51 | M12*40 | 1581Set |
5 | ABF-100D | 3800 | 1650 | 10180 | 11590 | 11770 | 10530 | 53 | M12*40 | 1643Set |
6 | ABF-104D | 3800 | 1650 | 10460 | 11870 | 12050 | 10810 | 54 | M12*40 | 1674Set |
Note: 1.The overall plane thickness is 4mm
2.The revers thickness is 8mm
3.The single edge thickness is 10mm
4.H3=500mm
Selection of Water Cooling Tower Molded Fan Stacks
Water Cooling Tower Molded Fan Stacks are an essential component of cooling towers, and their performance and quality directly affect the operational efficiency and service life of the cooling tower. Selecting the appropriate fiberglass fan stacks requires a comprehensive consideration of various factors, including the type of cooling tower, operating environment, material characteristics, design optimization, and the reliability of the supplier. Below is a detailed explanation of how to select cooling tower fiberglass fan stacks:
I. Performance Characteristics of Water Cooling Tower Molded Fan Stacks
-
Water Cooling Tower Molded Fan Stacks High Corrosion Resistance
Fiberglass materials possess excellent corrosion resistance, capable of withstanding the erosion of common acids, alkalis, and salts encountered during the operation of cooling towers, thereby extending the service life of the fan stacks. -
Water Cooling Tower Molded Fan Stacks High Strength
Fiberglass fan stacks are manufactured using high-strength epoxy fiberglass molding processes, which provide high mechanical strength and the ability to withstand significant wind pressure and airflow impact. -
Water Cooling Tower Molded Fan Stacks Lightweight
The density of fiberglass materials is relatively low, making the fan stacks lightweight and easy to install and maintain. -
Water Cooling Tower Molded Fan Stacks Good Aerodynamic Performance
Fiberglass fan stacks are typically designed with streamlined shapes to effectively reduce air resistance, increase airflow and pressure, and enhance the cooling efficiency of the cooling tower.
-
Water Cooling Tower Molded Fan Stacks UV Resistance and Aging Prevention
The surface of fiberglass fan stacks is often treated with special coatings, such as UV-resistant layers, to extend their service life and color stability under strong sunlight.
II. Key Considerations for Selecting Water Cooling Tower Molded Fan Stacks
(i) Water Cooling Tower Molded Fan Stacks Selection Based on Cooling Tower Type and Specifications
-
Counterflow Cooling Towers Water Cooling Tower Molded Fan Stacks
The Water Cooling Tower Molded Fan Stacks design for counterflow cooling towers typically requires higher strength and better aerodynamic performance to accommodate higher wind pressure and complex airflow organization. -
Crossflow Cooling Towers Water Cooling Tower Molded Fan Stacks
The Water Cooling Tower Molded Fan Stacks design for crossflow cooling towers is relatively simpler but must consider the horizontal airflow characteristics to ensure effective airflow guidance. -
Size Of Water Cooling Tower Molded Fan Stacks
The diameter and height of the Water Cooling Tower Molded Fan Stacks should be matched with the overall design of the cooling tower to ensure smooth airflow and prevent airflow short-circuiting.
(ii) Water Cooling Tower Molded Fan Stacks Selection Based on Operating Conditions of the Cooling Tower
-
Airflow and Pressure
The airflow and pressure of the Water Cooling Tower Molded Fan Stacks are critical factors affecting the cooling efficiency of the cooling tower. The fan stacks should be selected based on the design parameters and actual operating conditions of the cooling tower to provide sufficient airflow and pressure. -
Air-to-Water Ratio
The air-to-water ratio is an important parameter for cooling tower operation, determining the heat exchange efficiency between cold air and hot water. When selecting Water Cooling Tower Molded Fan Stacks, their impact on the air-to-water ratio should be considered to ensure optimal operation of the cooling tower. -
Environmental Temperature and Humidity
If the cooling tower operates in a high-temperature and high-humidity environment, the Water Cooling Tower Molded Fan Stacks need to have better corrosion resistance and aging resistance.
(iii) Water Cooling Tower Molded Fan Stacks Selection Based on Material and Manufacturing Processes
-
Water Cooling Tower Molded Fan Stacks High-Strength Epoxy Fiberglass Molding
Water Cooling Tower Molded Fan Stacks manufactured using this process feature high strength and precision, ensuring the performance and quality of the fan stacks. -
Water Cooling Tower Molded Fan Stacks Hollow Structure
Hollow-structured Water Cooling Tower Molded Fan Stacks offer the advantages of being lightweight and strong, but precautions should be taken to prevent internal water seepage and freezing that could damage the fan stacks. -
Water Cooling Tower Molded Fan Stacks Surface Treatment
The surface of the Water Cooling Tower Molded Fan Stacks is often specially treated, such as with UV-resistant coatings, to extend their service life and color stability under strong sunlight.
(iv) Water Cooling Tower Molded Fan Stacks Selection Based on Design Optimization
-
Water Cooling Tower Molded Fan Stacks Hyperbolic Design
The hyperbolic Water Cooling Tower Molded Fan Stacks design can effectively reduce air resistance, improve airflow uniformity, and reduce stress on the fan stacks. The geometric parameters of the hyperbolic fan stacks (such as the throat diameter, the ratio of the distance from the throat to the top of the tower to the total height of the tower, etc.) need to be optimized based on specific operating conditions. Extended Water Cooling Tower Molded Fan Stacks
In some applications, extended Water Cooling Tower Molded Fan Stacks can bring the outlet to a position higher than the existing motor outside the fan stacks, enhancing UV stability. This is suitable for situations where the exhaust gases need to be directed outside of enclosed spaces.
(v) Water Cooling Tower Molded Fan Stacks Selection Based on Installation and Maintenance Requirements
-
Water Cooling Tower Molded Fan Stacks Ease of Installation
Selecting Water Cooling Tower Molded Fan Stacks that are easy to install can reduce installation time and costs. For example, some fan stacks are designed with special installation structures that allow for quick and secure attachment to the cooling tower. -
Water Cooling Tower Molded Fan Stacks Ease of Maintenance
Although fiberglass Water Cooling Tower Molded Fan Stacks require relatively simple maintenance, regular inspection and upkeep are still necessary. Choosing fan stacks that are easy to maintain can reduce maintenance costs.
Water Cooling Tower Molded Fan Stacks Features
This product is a standardized product with high production efficiency,facilitating fast, large-scale production,and automated production.
The products produced by the molding process have high dimensional accuracy, no need to cut the edges,no deformation, and very convenient installation.
The interal and external surfaces of the product are smooth and contain anti UV agents, which have strong weather resistance and do not require secondary modification.
The product has a reasonable structural design, high vibration resistance, andeffectively avoids vibration.
The product is high-temperature pressed,therefore the product has high density,standardized molding, and no defects.
Water Cooling Tower Molded Fan Stacks Application
The application range is: Industrial water cooling,Air compressor, Aluminum profile processing, Steam turbine, Power generation, Tannery, Electric furnace, Freezing Series, Air conditioning cooling system

Water Cooling Tower Molded Fan Stacks Shippment
Packing:
Wooden pallet.
Delivery time:
With in 10 days.

Our Services Of Water Cooling Tower Molded Fan Stacks
-Pre-sale services
Based on the clients' requirements, we will offer product pictures, videos, quotation,information,
engineering drawings until you satisfied with it. Warmly welcome to visit our factory.
-Sale services
1 Providing production schedule photos to ensure you know every process.
2 Our experienced technician are available on the phone also internet, the clients can get instance
guidance by telephone,email, online service anytime, anywhere.
3 Also can arrange experienced technician to clients site for installation guidance, commissioning and training etc.
-After-sale services
Normally, the equipment warranty is 12 months since installation. We will keep in touch with our clients
to follow up the working condition of our machines, and offer support for maintenance.
Why choose us?
1. Highest quality
We are the manufacturer who adopts import raw materials. It is cheap price and guaranteed quality.
2. Most competitive price
We can adjustment the price according to your market demand’s changes,and also can launch a series of promotional activities in a bad economic environment.
3. Professional
We are specialized in producing and sells as development, methods and handling. We have 16 years experience.
4. Best service
Answering emails and solving questions timely. Delivery and update information on time.
Trust, good quality and service are the basic of long term business.