You are here: Home » Cooling Tower Part » Cooling Tower Motor » Reduced Speed Cooling Tower Belt Motor

loading

Reduced Speed Cooling Tower Belt Motor

Cooling tower cast iron motor is a type of motor designed specifically for the use environment of cooling towers. Its casing is mainly made of cast iron material, which has strong mechanical strength and durability, and is suitable for harsh working conditions.
  • YCCL

  • PT

  • 10 days

Voltage:
Material:
Power:
Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Product Description

Cooling tower belt reducer motor is a mechanical device specially used for cooling tower fan drive. It converts the high speed of the motor into the low speed required by the cooling tower fan through the coordination of the motor, the decelerating device and the belt transmission system, so as to achieve efficient fan operation. The following is a detailed introduction to the cooling tower belt reducer motor:



Reduced Speed Cooling Tower Belt Motor Basic composition



1. Reduced Speed Cooling Tower Belt Motor


Usually, three-phase asynchronous motors or high-efficiency motors are used, which have stable performance and long service life.



2. Reduced Speed Cooling Tower Belt Motor Speed Reduction Device


It is mainly composed of a reduction box (worm gear, helical gear or planetary gear, etc.) to reduce the speed and provide greater torque.



3. Reduced Speed Cooling Tower Belt Motor Belt Drive System


Includes a pulley and a drive belt for transmitting the power output of the deceleration device to the cooling tower fan shaft.



Reduced Speed Cooling Tower Belt Motor Working principle


The motor provides power through rotation, reduces the speed and increases the torque through the decelerating device, and then transmits the power to the fan through the belt transmission system, thereby driving the fan blade to rotate, ensuring the air circulation in the cooling tower and improving the cooling efficiency.



Reduced Speed Cooling Tower Belt Motor Advantage




1. Reduced Speed Cooling Tower Belt Motor Simple structure


The belt drive is easy to maintain and replace, and the overall structure is relatively simple.



2. Reduced Speed Cooling Tower Belt Motor Low cost


The belt drive solution is more economical than the direct drive method.



3. Reduced Speed Cooling Tower Belt Motor You're adaptable


The belt drive can adjust the speed by replacing the belt pulley to flexibly meet the operating needs of different cooling towers.


Reduced Speed Cooling Tower Belt Motor Size Measurement



8

Type
                                    Moumting dimensions

      Overall simensions
B  L1  H E F D G K T M n-S L  AC AD  P
90S 208 50 12 32 8 φ24 20 M8 30 φ165 4-φ12 258 φ175 160 φ200
90L 233 50 12 32 8 φ24 20 M8 30 φ165 4-φ12 283 φ175 160 φ200
100 262 60 14 40 8 φ28 24 M8 30 φ215 4-φ12 322 φ205 190 φ250
112 282 60 14 40 8 Φ28 24 M10 25 φ215 4-φ25 342 φ230 198 φ250
132S 316 80 18 56 10 φ38 33 M12 30 φ265 4-φ25 396 φ264 215 φ300
132M 354 80 18 56 10 φ38 33 M12 30 φ265 4-φ25 434 φ264 215 φ300
160M 426 110 20 85 12 Φ42 37 M16 40 Φ300 4-φ16 536 Φ325 255 φ350
160L 470 110 20 85 12 φ42 37 M16 40 φ300 4-Φ16 580 φ325 255 φ350
180m 478 110 18 80 14 Φ48 42.5 M16 40 φ300 4-φ19 588 Φ360 285 φ350
180L 516 110 18 80 14 φ48 42.5 M16 40 φ300 4-φ19 626 φ360 285 φ350


How To Select Cooling Tower Belt Motor

I. Reduced Speed Cooling Tower Belt Motor Types

(1) Reduced Speed Cooling Tower Belt Motor External Cooling Tower Motors

External cooling tower motors are installed outside the cooling tower, making them easy to install and maintain. They also allow for more convenient maintenance and repair of the motor. However, since external cooling tower motors are exposed to the elements such as wind and sunlight, it is important to consider their protection level when selecting them.

(2) Reduced Speed Cooling Tower Belt Motor Internal Cooling Tower Motors

Internal cooling tower motors are installed inside the cooling tower, which requires higher stability in operation. When selecting these motors, it is necessary to consider parameters such as torque, speed, and power.

II.Reduced Speed Cooling Tower Belt Motor Key Considerations for Selecting Cooling Tower Motors

(1) Reduced Speed Cooling Tower Belt Motor Understanding Cooling Tower Parameters

Before selecting a motor, it is essential to understand the parameters of the cooling tower, such as water flow rate, water temperature, air flow rate, and air pressure. This information helps determine the power and speed of the motor. If the motor power is too high or too low, it will affect the normal operation of the cooling tower.

(2) Reduced Speed Cooling Tower Belt Motor Determining Motor Power and Speed

When selecting a motor, it is necessary to determine its power and speed. Typically, internal motors have lower power and speed, while external motors have higher power and speed. Additionally, it is important to consider the motor's efficiency and power factor to ensure high energy efficiency.

(3) Reduced Speed Cooling Tower Belt Motor Considering Motor Protection Level

The protection level of cooling tower motors should be IP55 or higher to ensure that the motor is not affected by external factors such as moisture.

(4) Reduced Speed Cooling Tower Belt Motor Considering Motor Corrosion Resistance

Since the internal environment of a cooling tower is relatively complex, it is necessary to choose a motor with good corrosion resistance. Generally, cooling tower motors should be made of corrosion-resistant materials to ensure long-term stable operation.

III. Reduced Speed Cooling Tower Belt Motor Performance Parameters of Cooling Tower Motors

(1) Reduced Speed Cooling Tower Belt Motor Power

Power is one of the most important parameters of a motor. The power of a cooling tower motor is usually expressed in kilowatts (kW). The higher the power, the greater the torque of the motor, allowing it to handle larger loads. It is necessary to select the appropriate power based on the cooling tower's working load and speed. If the power is too low, the motor may not meet the cooling tower's requirements, while too much power will waste energy and resources.

(2) Reduced Speed Cooling Tower Belt Motor Speed

Speed is another important parameter of a motor. The speed of a cooling tower motor is usually expressed in revolutions per minute (RPM). The higher the speed, the higher the efficiency of the motor, but it will also generate more noise and vibration. It is necessary to select the appropriate speed based on the cooling tower's working load and speed. If the speed is too high, the motor may produce excessive noise and vibration, affecting the working environment and employee health.

(3) Reduced Speed Cooling Tower Belt Motor Noise

Choosing a cooling tower motor with low noise levels can reduce the impact of noise on workers and is also beneficial for the company's image.

(4) Reduced Speed Cooling Tower Belt Motor Durability

Choosing a cooling tower motor with a long lifespan can reduce replacement and maintenance costs and is also beneficial for saving company costs.

IV. Reduced Speed Cooling Tower Belt Motor Maintenance and Care of Cooling Tower Motors

(1) Reduced Speed Cooling Tower Belt Motor Regularly Check Motor Operation

Regularly check the temperature, noise, vibration, protection level, and lubrication of the motor.

(2) Reduced Speed Cooling Tower Belt Motor Regularly Check Electrical Connections

Regularly check the electrical connections of the motor, such as whether the cable connections are loose and whether the grounding is good.

(3) Reduced Speed Cooling Tower Belt Motor Regularly Replace Motor Lubricant

Regularly replace the motor lubricant to ensure the motor's lubrication performance.

(4) Reduced Speed Cooling Tower Belt Motor Regularly Clean the Inside of the Cooling Tower

Regularly clean the inside of the cooling tower to ensure the motor's heat dissipation performance.

V. Reduced Speed Cooling Tower Belt Motor Suggestions for Purchasing Cooling Tower Motors

(1) Reduced Speed Cooling Tower Belt Motor Purchase Motors with High Quality

High-quality cooling tower motors have the advantages of high efficiency, low noise, and durability. To purchase high-quality cooling tower motors, you can refer to the reviews of other users or choose products from well-known brands.

(2) Reduced Speed Cooling Tower Belt Motor Purchase Motors with Appropriate Power

When purchasing a cooling tower motor, it is necessary to consider the actual usage of the equipment. If the cooling tower is small, purchasing a motor with appropriate power can meet the equipment's needs while also reducing energy consumption and costs.

(3) Reduced Speed Cooling Tower Belt Motor Purchase Motors Suitable for the Operating Environment

When purchasing a cooling tower motor, it is necessary to consider the operating environment of the equipment, such as temperature and humidity. The performance and quality of cooling tower motors can vary in different operating environments. Therefore, it is important to select a cooling tower motor that is suitable for the operating environment.

(4) Reduced Speed Cooling Tower Belt Motor Purchase Motors with Reasonable Prices

A cooling tower motor that is too expensive may increase costs, while one that is too cheap may affect the quality and lifespan of the equipment. Therefore, it is important to choose a cooling tower motor with a reasonable price.



Reduced Speed Cooling Tower Belt Motor Application



Industrial cooling tower

Plant cooling system

Cooling equipment in HVAC system



Reduced Speed Cooling Tower Belt Motor Packing



Packing:

wooden case. 


Delivery time:

With in 10 days.


包装820

Our Services Of Reduced Speed Cooling Tower Belt Motor


-Pre-sale services


Based on the clients' requirements, we will offer product pictures, videos, quotation,information,

engineering drawings until you satisfied with it. Warmly welcome to visit our factory.



-Sale services


1 Providing production schedule photos to ensure you know every process.

2 Our experienced technician are available on the phone also internet, the clients can get instance

guidance by telephone,email, online service anytime, anywhere.

3 Also can arrange experienced technician to clients site for installation guidance, commissioning and training etc.


-After-sale services


Normally, the equipment warranty is 12 months since installation. We will keep in touch with our clients

to follow up the working condition of our machines, and offer support for maintenance.


Why choose us?


1. Highest quality


We are the manufacturer who adopts import raw materials. It is cheap price and guaranteed quality.

2. Most competitive price


We can adjustment the price according to your market demand’s changes,and also can launch a series of promotional activities in a bad economic environment.

3. Professional


We are specialized in producing and sells as development, methods and handling. We have 16 years experience.

4. Best service


Answering emails and solving questions timely. Delivery and update information on time.
Trust, good quality and service are the basic of long term business.



Previous: 
Next: 
Consult Your Cooling Tower Expert
Cooling Tower Parts
COOLING TOWER PARTS SUPPLIER
OEM Brands
Quick Links
COOLING TOWER PARTS SUPPLIER
Cooling Tower Parts
OEM Brands
Quick Links
COPYRIGHT © 2024 ZHEJIANG AOSHUAI REFRIGERATION CO., LTD. ALL RIGHTS RESERVED.