Cooling Tower Pump sizing refers to the scientific calculation and rational selection of the flow rate, head, and power of the cooling tower pump during the design process of the cooling tower system. The correct selection of water pumps is a key factor in ensuring efficient, stable, and energy-saving operation of the cooling tower pump system.

In the entire cooling tower pump system, the cooling tower water pump is responsible for transporting hot water from the heat exchange equipment to the cooling tower, and then returning the cooled water to the system, which is the core power source of circulating cooling water.
The operational efficiency of the cooling tower pump directly determines the energy consumption level of the system. A reasonable Cooling Tower Pump Sizing can meet cooling needs while minimizing power consumption.
Flow rate is the fundamental parameter for cooling tower pump sizing, typically determined based on the cooling load of the system. Common experience points include:
1)1.8-2.2 m ⊃3;/h/cold ton (RT)
2)Or accurately determined based on the heat load calculation formula
A low flow rate can affect the cooling effect, while a high flow rate can increase the operating cost of the cooling tower pump system.
Head is the ability of a water pump to overcome system resistance, mainly including:
1)Cooling tower height difference
2)Pipeline resistance along the way
3)Local resistance of valves, elbows, etc
4)Internal resistance of heat exchanger and cooling tower
The power of a water pump is determined by the flow rate, head, and efficiency. When sizing the cooling tower pump, priority should be given to selecting pump models that operate in the high-efficiency range to improve the energy efficiency ratio of the entire cooling tower pump system.
Calculating the required cooling capacity of the system based on the device's heat generation or air conditioning load is a prerequisite for selecting a water pump.
Calculate the circulating water flow required for the cooling tower pump based on the parameters of the cooling tower and the design temperature difference.
Calculate the total dynamic head of the cooling tower pump system by taking into account the length, diameter, material, and resistance of the associated equipment.
On the premise of meeting the requirements of flow rate and head, select a cooling tower pump with an operating point close to the high-efficiency zone, and match the motor power reasonably.
Excessive selection of water pumps can lead to long-term low load operation of the system, increase energy consumption, and shorten equipment lifespan.
Unreasonable pipeline design can significantly increase system resistance and affect the overall performance of the cooling tower pump system.
Neglecting variable frequency control in modern cooling systems can limit the energy-saving potential of cooling tower pumps.
Cooling Tower Fill | Cooling Tower Fan | Cooling Tower Speed Reduer | Cooling Tower Motor | Cooling Tower Drift Eliminator | Cooling Tower Fan Stacks | Cooling Tower Sprinkler Head | Cooling Tower Air Inlet Louver | Cooling Tower Basin | Cooling Tower Casing | Cooling Tower Nozzle | Cooling Tower Spray Pan | Cooling Tower Plastic Accessories
Marley/Spx | Liang Chi | Kingsun | EBABA/Shinwa | Spindle | Kuken | BAC | Brentwood | Evapco | Royden
HOME | PRODUCTS | OEM BRANDS | ABOUT US | BLOG | FAQ | CONTACT US
Cooling Tower Fill Cooling Tower Fan Cooling Tower Speed Reduer Cooling Tower Motor Cooling Tower Drift Eliminator Cooling Tower Fan Stacks Cooling Tower Sprinkler Head Cooling Tower Air Inlet Louver Cooling Tower Basin Cooling Tower Casing Cooling Tower Nozzle Cooling Tower Spray Pan Cooling Tower Plastic Accessories